FUEL SYSTEM
| Standard fuel pressure
|
at idle
|
300 to 530 kPa (3.1 to 5.4 kgf/cm2, 44 to 77 psi)
|
| Fuel pressure: for 5 minutes after engine has stopped
|
Standard fuel pressure
|
98 kPa (1.0 kgf/cm2, 14.2 psi) or more
|
| Standard fuel pressure (for high pressure)
|
at 3000 rpm
(shift lever in P, engine warmed up and A/C off)
|
2400 to 20000 kPag
|
FUEL INJECTOR (for Port Injection)
| Fuel injector assembly
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
11.6 to 12.4 Ω
|
| Standard injection volume
|
54 to 65 cc (3.3 to 4.0 cu.in.) per 15 seconds
|
| Difference between each fuel injector
|
11 cc (0.7 cu.in.) or less
|
| Standard fuel drop
|
1 drop or less per 20 minutes
|
FUEL INJECTOR (for Direct Injection)
| Fuel injector assembly
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
1.34 to 1.64 Ω
|
FUEL PRESSURE SENSOR
| No. 2 fuel pressure sensor
|
Tester Connection
|
Condition
|
Specified Condition
|
| 2 (PFL) - 3 (E2)
|
Pressure not applied to fuel pressure sensor
|
Approximately 0.56 to 0.94 V*
|
*: The output voltage changes depending on the voltage applied to the terminals.
FUEL PRESSURE SENSOR (for High Pressure)
| Fuel pressure sensor
|
Tester Connection
|
Condition
|
Specified Condition
|
| 3 (PR) - 2 (E2)
|
Pressure not applied to fuel pressure sensor
|
Approximately 0.4 to 0.6 V*
|
*: The output voltage changes depending on the voltage applied to the terminals.
FUEL PUMP
| Fuel pump
|
Tester Connection
|
Specified Condition
|
| U - V
|
0.05 to 3.0 Ω
|
| V - W
|
0.05 to 3.0 Ω
|
| U - W
|
0.05 to 3.0 Ω
|
FUEL PUMP (for High Pressure)
| Fuel pump assembly
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
0.45 to 0.55 Ω
|
FUEL SENDER GAUGE ASSEMBLY
| Fuel sender gauge assembly
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
Float level is F
|
4.255 to 4.605 V*
|
| Between F and E
|
0.345 to 4.605 V*
(Gradually changes)
|
| Float level is E
|
0.345 to 0.695 V*
|
| No. 2 fuel sender gauge assembly
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
Float level is F
|
4.255 to 4.605 V*
|
| Between F and E
|
0.345 to 4.605 V*
(Gradually changes)
|
| Float level is E
|
0.345 to 0.695 V*
|
*: The output voltage changes depending on the voltage applied to the terminals.