RM36D0EC
_57
Power Source / Network
_083089
M20D-FKS BATTERY / CHARGING
_0402337
CHARGING SYSTEM
D
M20D-FKS BATTERY / CHARGING CHARGING SYSTEM DIAGNOSIS SYSTEM
DLC3 (Data Link Connector 3)
BATTERY VOLTAGE
- Standard voltage:
11 to 14 V
If the voltage is below 11 V, replace or recharge the battery.