87130K
1.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Manual Air Conditioning System)
| *a | Component without harness connected
(No. 1 Blower Damper Servo Sub-assembly) |
| *b | Fresh Side |
| *c | Recirculation Side |
| *d | 94.4° to 101.4° |
| *e | 180° |
Apply battery voltage to the No. 1 blower damper servo sub-assembly and check the operation of the motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 2 |
Turns to the "RECIRCULATION" side smoothly |
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 1 |
Turns to the "FRESH" side smoothly |
If the result is not as specified, replace the No. 1 blower damper servo sub-assembly.
87130K
2.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System and M15B-FKS, M15C-FKS, 8ZR-FXE)
| *a | Component without harness connected
(No. 1 blower damper servo sub-assembly) |
Apply battery voltage to the No. 1 blower damper servo sub-assembly and check the operation.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 5 |
Motor operate |
If the result is not as specified, replace the No. 1 blower damper servo sub-assembly.