RM3660EC _57 Power Source / Network _080743 NETWORKING _0600591 CXPI COMMUNICATION SYSTEM U

NETWORKING  CXPI COMMUNICATION SYSTEM  FAIL-SAFE CHART  


CXPI COMMUNICATION FAIL-SAFE


a.

When there is a CXPI communication malfunction (communication stop), each load operates as follows.

Power Distribution Box Assembly
Load Communication Stop with Ignition Switch ON Communication Stop with Ignition Switch Off Operation When Communication Returns to Normal
Operation During Communication Stop Reset Timing Operation During Communication Stop Reset Timing
Taillight Forced on Ignition switch off or power source reset Forced off Power source reset According to communication signals
Rear fog light Forced off Ignition switch off or power source reset Forced off Power source reset According to communication signals
Rear window defogger Forced off Ignition switch off or power source reset - - According to communication signals
Mirror heater*1 Forced off Ignition switch off or power source reset - - According to communication signals
Power retract mirror Forced off Ignition switch off or power source reset Forced off Power source reset According to communication signals
Front fog light*2 Forced off Ignition switch off or power source reset Forced off Power source reset According to communication signals
Dome cut relay Forced off Ignition switch off or power source reset Forced off Power source reset According to communication signals

*1: w/ Mirror Heater

*2: w/ Front Fog Light