RM3660EC _57 Power Source / Network _080760 NR Series BATTERY / CHARGING _0393834 BATTERY CURRENT SENSOR A

NR Series BATTERY / CHARGING  BATTERY CURRENT SENSOR  INSTALLATION  


PROCEDURE

Hide 28850C 1.INSTALL BATTERY STATE SENSOR ASSEMBLY

a.

Engage the 2 claws to install the battery state sensor assembly to the battery current sensor holder.


b.

Engage the wire harness clamp.


c.

Connect the battery state sensor assembly connector.


d.

Install the battery state sensor assembly to the battery and tighten the nut.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


e.

Connect the engine wire and earth wire to the battery state sensor assembly with the nut.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


Hide 2. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART