RM3660EC _55 Steering _080761 POWER ASSIST SYSTEMS _0392052 POWER STEERING SYSTEM(for Gasoline Model) D

POWER ASSIST SYSTEMS  POWER STEERING SYSTEM(for Gasoline Model)  FREEZE FRAME DATA  


FREEZE FRAME DATA (for Type A)


NOTICE:
·

It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specification.

·

Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the GTS.



a.

Turn the ignition switch off.


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Check the freeze frame data on the GTS.

Chassis > EMPS
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Total distance traveled Min.: 0, Max.: 16777215 - -
Total Distance Traveled - Unit Total Distance Traveled unit km / mile - -
Vehicle Speed Vehicle speed from speedometer Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH)
·

0 km/h (0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
Engine Revolution Engine speed Min.: 0 rpm
Max.: 12800 rpm
No significant fluctuation Engine running at a constant speed
Battery Voltage Battery voltage Min.: 0.00 V
Max.: 25.00V
11 to 14 V -
Steering Wheel Torque Steering wheel torque Min.: -25.000 Nm
Max.: 25.001 Nm
Value changes in proportion to steering effort
- Engine running and steering wheel being turned
-
Steering Angle Velocity Steering angle speed Min.: -32768 deg/s
Max.: 32767 deg/s
Value changes in proportion to steering effort
- Engine running and steering wheel being turned
-
Steering Angle Steering angle Min.: -3072.0 deg
Max.: 3070.5 deg
- -
IG Power Supply IG power source voltage Min.: 0.00 V
Max.: 25.00V
10.5 to 16 V Ignition switch ON
PIG Power Supply PIG power source voltage Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Thermistor Temperature ECU substrate temperature Min.: -50.0°C (-58.0°F)
Max.: 200.0 °C (392.0 °F)
-50°C to 200°C (-58°F to 392°F) -
Power Source Operating state of engine Operating State or Stopped State Operating State: Engine running
Stopped State: Engine stopped
-
PS Assist Signal Status of the record of power steering assist signal OFF or ON OFF: Assist stop
ON: Under an assist
-
Torque Sensor 1 Output Torque sensor 1 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 2 Output Torque sensor 2 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 3 Output Torque sensor 3 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 4 Output Torque sensor 4 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Motor 1 U Phase Current Motor 1 terminal current (U phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 V Phase Current Motor 1 terminal current (V phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 W Phase Current Motor 1 terminal current (W phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 U Phase Duty Motor 1 U phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 V Phase Duty Motor 1 V phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 W Phase Duty Motor 1 W phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 U Phase Terminal Voltage Motor 1 terminal voltage (U phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 V Phase Terminal Voltage Motor 1 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 W Phase Terminal Voltage Motor 1 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 Power Supply Power supply voltage to active motor 1 Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Motor 2 U Phase Current Motor 2 terminal current (U phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 V Phase Current Motor 2 terminal current (V phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 W Phase Current Motor 2 terminal current (W phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 U Phase Duty Motor 2 U phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 V Phase Duty Motor 2 V phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 W Phase Duty Motor 2 W phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 U Phase Terminal Voltage Motor 2 terminal voltage (U phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 V Phase Terminal Voltage Motor 2 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 W Phase Terminal Voltage Motor 2 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 Power Supply Power supply voltage to active motor 2 Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Motor Rotation Angle 1 Motor rotation angle 1 Min.: 0.0 deg
Max.: 360.1 deg
Value changes from 0 to 360°
·

Engine running and steering wheel being turned

·

*1


Motor Rotation Angle 2 Motor rotation angle 2 Min.: 0.0 deg
Max.: 360.1 deg
Value changes from 0 to 360°
·

Engine running and steering wheel being turned

·

*1


Motor Rotation Angle 3 Motor rotation angle 3 Min.: 0.0 deg
Max.: 360.1 deg
- *1
Motor Rotation Angle 4 Motor rotation angle 4 Min.: 0.0 deg
Max.: 360.1 deg
- *1
Motor Rotation Angle Sensor 1 Sin Voltage Rotation angle sensor Sin1 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 1 Cos Voltage Rotation angle sensor Cos1 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 2 Sin Voltage Rotation angle sensor Sin2 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 2 Cos Voltage Rotation angle sensor Cos2 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 3 Sin Voltage Rotation angle sensor Sin3 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 3 Cos Voltage Rotation angle sensor Cos3 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Actual Current (Q Axis) Detected current flow to motor (detected current of axis q) Min.: -327.68 A
Max.: 327.67 A
- -
Command Value Current (Q Axis) Target current flow to motor (requested current of axis q) Min.: -327.68 A
Max.: 327.67 A
- -
Motor Actual Current 2 (D Axis) Detected current flow to motor (detected current of axis d) Min.: -327.68 A
Max.: 327.67 A
- -
Command Value Current 2 (D Axis) Target current flow to motor (requested current of axis d) Min.: -327.68 A
Max.: 327.67 A
- -
Motor Rotation Angle Motor rotation angle (detected by rotation sensor) 0.0 to 360.1 deg / Unknown During steering operation, motor rotation angle value changes from 0 to 360° Engine running and steering wheel being turned
Final Motor Current Limited (Q Axis) Final motor current set limit (request current of axis q) Min.: 0.00 A
Max.: 327.67 A
- -
Steering Angle Sensor Signal State State of steering angle sensor signal Usable, Unlearned, Sensor Fault, Communication Fault - -
Eco-Run Control Mode State of stop and start system Eco Mode0, Eco Mode1, Eco Mode2, Eco Mode3 or Eco Mode4 Eco Mode0: Ignition switch ON (Before engine started)
Eco Mode1: Engine running
Eco Mode2: Engine stop requested
Eco Mode3: Engine stopped
Eco Mode4: Engine restarting
-
CAN Vehicle Speed (Speed Sensor RR) Speed sensor RR value sent via CAN Min.: 0 km/h (0 MPH)
Max.: 255 km/h (158 MPH)
·

0 km/h (0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Vehicle Speed (Speed Sensor RL) Speed sensor RL value sent via CAN Min.: 0 km/h (0 MPH)
Max.: 255 km/h (158 MPH)
·

0 km/h (0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Vehicle Speed (SP1) Vehicle speed input value sent via CAN (equal to value indicated on speedometer) Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH)
·

0 km/h (0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Steering Angle Speed (SSAV) Steering wheel turning speed value sent via CAN Min.: -32768 deg/s
Max.: 32767 deg/s
- -
Control State Information Control statusinformation Min.: 0
Max.: 65535
- -
ASIC State Information ASIC State Information Min.: 0
Max.: 1
- *1
ECU Overheat Prevention Part Internal component of ECU for which overheat protection control is performed No Target Part, Inverter MOS, Power Supply Relay MOS, Custom IC, Choke Coil, H Bridge MOS, Motor Relay MOS, Around Microcomputer or DBC - -
ECU Estimate Temperature of Overheat Prevention Part Estimated temperature of internal component of ECU for which overheat protection control is performed Min.: -50.0°C (-58.0°F)
Max.: 200.1 °C (392.2 °F)
- -
Motor Overheat Prevention Part Internal component of motor for which overheat protection control is performed No Target Part, Motor - -
Motor Estimate Temperature of Overheat Prevention Part Estimated temperature of internal component of motor for which overheat protection control is performed Min.: -50.0°C (-58.0°F)
Max.: 200.1 °C (392.2 °F)
- -
HINT:

*1: Depending on the vehicle, this item may not be displayed.




FREEZE FRAME DATA (for Type B)


NOTICE:
·

It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specification.

·

Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the GTS.



a.

Turn the ignition switch off.


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Check the freeze frame data on the GTS.

Chassis > EMPS
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Total distance traveled Min.: 0, Max.: 16777215 - -
Total Distance Traveled - Unit Total Distance Traveled unit km / mile - -
Vehicle Speed Vehicle speed from speedometer Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH)
·

0 km/h (0.0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
Engine Revolution Engine speed Min.: 0 rpm
Max.: 12800 rpm
No significant fluctuation Engine running at a constant speed
Battery Voltage Auxiliary battery voltage Min.: 0.00 V
Max.: 25.00V
11 to 14 V -
Steering Wheel Torque Steering wheel torque Min.: -25.000 Nm
Max.: 25.001 Nm
Value changes in proportion to steering effort
- Engine running and steering wheel being turned
-
Steering Angle Velocity Steering angle speed Min.: -32768 deg/s
Max.: 32767 deg/s
Value changes in proportion to steering effort
- Engine running and steering wheel being turned
-
Steering Angle Steering angle Min.: -3072.0 deg
Max.: 3070.5 deg
- -
Status of Vehicle Power (IGP PT2) State of IGP power source(PT2) OFF or ON OFF: Ignition switch off
ON: Ignition switch ON
-
Status of Vehicle Power (IGP PT1) State of IGP power source(PT1) OFF or ON OFF: Ignition switch off
ON: Ignition switch ON
-
Status of Vehicle Power (IGP PDC) State of IGP power source(PDC) OFF or ON OFF: Ignition switch off
ON: Ignition switch ON
-
Status of Vehicle Power (IGR PDC) State of IGR power source(PDC) OFF or ON OFF: Ignition switch off
ON: Ignition switch ON
-
IG Power Supply IG power source voltage Min.: 0.00 V
Max.: 25.00V
8 to 16 V Ignition switch ON
PIG Power Supply PIG power source voltage Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Thermistor Temperature ECU substrate temperature Min.: -50.0°C (-58.0°F)
Max.: 200.0 °C (392.0 °F)
-50°C to 200°C (-58°F to 392°F) -
Power Source Operating state of hybrid system Operating State or Stopped State Operating State: Engine running
Stopped State: Engine stopped
-
PS Assist Signal Status of the record of power steering assist signal Assist Stop or Under an Assist OFF: Assist stop
ON: Under an assist
-
Middle Voltage of Other Systems Middle voltage of other systems Min.: 0.00 V
Max.: 25.00 V
- *1
Torque Sensor 1 Output Torque sensor 1 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 2 Output Torque sensor 2 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 3 Output Torque sensor 3 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Torque Sensor 4 Output Torque sensor 4 output value Min.: -25.000 Nm
Max.: 25.001 Nm
- -
Motor 1 U Phase Current Motor 1 terminal current (U phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 V Phase Current Motor 1 terminal current (V phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 W Phase Current Motor 1 terminal current (W phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 1 U Phase Duty Motor 1 U phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 V Phase Duty Motor 1 V phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 W Phase Duty Motor 1 W phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 1 U Phase Terminal Voltage Motor 1 terminal voltage (U phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 V Phase Terminal Voltage Motor 1 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 W Phase Terminal Voltage Motor 1 terminal voltage (W phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 1 Power Supply Power supply voltage to active motor 1 Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Motor 2 U Phase Current Motor 2 terminal current (U phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 V Phase Current Motor 2 terminal current (V phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 W Phase Current Motor 2 terminal current (W phase) Min.: -327.68 A
Max.: 327.67 A
Value changes in proportion to steering effort Engine running and steering wheel being turned
Motor 2 U Phase Duty Motor 2 U phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 V Phase Duty Motor 2 V phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 W Phase Duty Motor 2 W phase duty Min.: 0.00%
Max.: 100.00%
- -
Motor 2 U Phase Terminal Voltage Motor 2 terminal voltage (U phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 V Phase Terminal Voltage Motor 2 terminal voltage (V phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 W Phase Terminal Voltage Motor 2 terminal voltage (W phase) Min.: 0.00 V
Max.: 100.00 V
- *1
Motor 2 Power Supply Power supply voltage to active motor 2 Min.: 0.00 V
Max.: 25.00 V
9 to 16 V Engine running and steering wheel being turned
Motor Rotation Angle 1 Motor rotation angle 1 Min.: 0.0 deg
Max.: 360.1 deg
Value changes from 0 to 360°
·

Engine running and steering wheel being turned

·

*1


Motor Rotation Angle 2 Motor rotation angle 2 Min.: 0.0 deg
Max.: 360.1 deg
Value changes from 0 to 360°
·

Engine running and steering wheel being turned

·

*1


Motor Rotation Angle 3 Motor rotation angle 3 Min.: 0.0 deg
Max.: 360.1 deg
- *1
Motor Rotation Angle 4 Motor rotation angle 4 Min.: 0.0 deg
Max.: 360.1 deg
- *1
Motor Rotation Angle Sensor 1 Sin Voltage Rotation angle sensor Sin1 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 1 Cos Voltage Rotation angle sensor Cos1 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 2 Sin Voltage Rotation angle sensor Sin2 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 2 Cos Voltage Rotation angle sensor Cos2 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 3 Sin Voltage Rotation angle sensor Sin3 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Motor Rotation Angle Sensor 3 Cos Voltage Rotation angle sensor Cos3 output voltage used for rotation angle calculation Min.: 0.00 V
Max.: 5.00 V
- -
Turn Counter 1 Turn counter 1 Min.: 0
Max.: 1024
- *1
Turn Counter 2 Turn counter 2 Min.: 0
Max.: 1024
- *1
Absolute Angle (Pinion Angle) Absolute angle (pinion angle) Min.: -32.768 rad
Max.: 32.768 rad
- *1
Steering Angle for the Steering Assembly Steering angle for the steering assembly Min.: -1877.5 deg
Max.: 1877.6 deg
- *1
Motor Actual Current (Q Axis) Detected current flow to motor (detected current of axis q) Min.: -327.68 A
Max.: 327.67 A
- -
Command Value Current (Q Axis) Target current flow to motor (requested current of axis q) Min.: -327.68 A
Max.: 327.67 A
- -
Motor Actual Current 2 (D Axis) Detected current flow to motor (detected current of axis d) Min.: -327.68 A
Max.: 327.67 A
- -
Command Value Current 2 (D Axis) Target current flow to motor (requested current of axis d) Min.: -327.68 A
Max.: 327.67 A
- -
Motor Rotation Angle Motor rotation angle (detected by rotation sensor) 0.0 to 360.1 deg / Unknown During steering operation, motor rotation angle value changes from 0 to 360° Engine running and steering wheel being turned
Final Motor Current Limited (Q Axis) Final motor current set limit (request current of axis q) Min.: 0.00 A
Max.: 327.67 A
- -
Steering Angle Sensor Signal State State of steering angle sensor signal Usable, Unlearned, Sensor Fault, Communication Fault - -
CAN Vehicle Speed (Speed Sensor RR) Speed sensor RR value sent via CAN Min.: 0 km/h (0.0 MPH)
Max.: 255 km/h (158 MPH)
·

0 km/h (0.0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Vehicle Speed (Speed Sensor RL) Speed sensor RL value sent via CAN Min.: 0 km/h (0.0 MPH)
Max.: 255 km/h (158 MPH)
·

0 km/h (0.0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Vehicle Speed (SP1) Vehicle speed input value sent via CAN (equal to value indicated on speedometer) Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH)
·

0 km/h (0.0 MPH): Engine running and vehicle stopped

·

No significant fluctuation: Engine running and vehicle driven at a constant speed


-
CAN Steering Angle Speed (SSAV) Steering wheel turning speed value sent via CAN Min.: -32768 deg/s
Max.: 32767 deg/s
- -
Control State Information Control statusinformation Min.: 0
Max.: 65535
- -
ASIC State Information ASIC State Information Min.: 0
Max.: 1
- -
ASIC State Information 2 ASIC State Information 2 Min.: 0
Max.: 1
- -
ECU Overheat Prevention Part Internal component of ECU for which overheat protection control is performed No Target Part, Inverter MOS, Power Supply Relay MOS, Custom IC, Choke Coil, H Bridge MOS, Motor Relay MOS, Around Microcomputer or DBC - -
ECU Estimate Temperature of Overheat Prevention Part Estimated temperature of internal component of ECU for which overheat protection control is performed Min.: -50.0°C (-58.0°F)
Max.: 200.1 °C (392.2 °F)
- -
Motor Overheat Prevention Part Internal component of motor for which overheat protection control is performed No Target Part, Motor - -
Motor Estimate Temperature of Overheat Prevention Part Estimated temperature of internal component of motor for which overheat protection control is performed Min.: -50.0°C (-58.0°F)
Max.: 200.1 °C (392.2 °F)
- -
Battery Voltage (System 2) Battery voltage (system 2) Min.: 0.00 V
Max.: 25.00V
- *1
IG Power Supply (System 2) IG power supply (system 2) Min.: 0.00 V
Max.: 25.00V
- *1
PIG Power Supply (System 2) PIG power supply (system 2) Min.: 0.00 V
Max.: 25.00V
- *1
Thermistor Temperature (System 2) Thermistor temperature (system 2) Min.: -50.0°C (-58.0°F)
Max.: 200.0 °C (392.1 °F)
- *1
Middle Voltage of Other Systems (System 2) Middle voltage of other systems (system 2) Min.: 0.00 V
Max.: 25.00V
- *1
Motor Actual Current (Q Axis) (System 2) Motor actual current (Q axis) (system 2) Min.: -327.68 A
Max.: 327.67 A
- *1
Command Value Current (Q Axis) (System 2) Command value current (Q axis) (system 2) Min.: -327.68 A
Max.: 327.67 A
- *1
Motor Actual Current 2 (D Axis) (System 2) Motor actual current 2 (D axis) (system 2) Min.: -327.68 A
Max.: 327.67 A
- *1
Command Value Current 2 (D Axis) (System 2) Command value current 2 (D axis) (system 2) Min.: -327.68 A
Max.: 327.67 A
- *1
Motor Rotation Angle (System 2) Motor rotation angle (system 2) Min.: 0.0 deg
Max.: 360.0 deg
- *1
Final Motor Current Limited (Q Axis) (System 2) Final motor current limited (Q axis) (system 2) Min.: 0 A
Max.: 327.67 A
- *1
ASIC State Information (System 2) ASIC state information (system 2) Min.: 0
Max.: 1
- *1
ASIC State Information 2 (System 2) ASIC State Information 2 (System 2) Min.: 0
Max.: 1
- *1
HINT:

*1: Depending on the vehicle, this item may not be displayed.