RM3660EC _58 Vehicle Interior _080733 HEATING / AIR CONDITIONING _0591215 AIR CONDITIONING SYSTEM(for Gasoline Model (NR Series) with Manual Air Conditioning System for Electrical Control Type) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model (NR Series) with Manual Air Conditioning System for Electrical Control Type)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Data List.


ii.

for Engine: Powertrain / Engine / Data List.



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE: 250 (pulse)

·

B/L: 281 (pulse)

·

FOOT: 287 (pulse)

·

F/D: 297 (pulse)

·

SHUT: 250 (pulse)

·

D/F: 272 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction*1
Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE: 250 (pulse)

·

B/L: 281 (pulse)

·

FOOT: 287 (pulse)

·

F/D: 297 (pulse)

·

SHUT: 250 (pulse)

·

D/F: 272 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction*1
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Evaporator Control Evaporator control Auto or Manual Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed -
A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Refrigerant High Pressure History Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *2

Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 and 257 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 241 and 348 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 220 and 256 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 250 and 297 pulses*

*: w/ Rear Air Duct