RM3660EC _57 Power Source / Network _080760 NR Series BATTERY / CHARGING _0394911 CHARGING SYSTEM U

NR Series BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


A443921E01
2.365,0.375 2.802,0.615 0.438,0.24 5.771,0.375 6.208,0.615 0.438,0.24 2.458,0.417 2.917,0.615 0.458,0.198 10 false C78 5.875,0.417 6.333,0.615 0.458,0.198 10 false A46

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage and resistance for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C78-53 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A46-1 (BATT) - C78-53 (E1) R - W-B Battery
(for measuring battery voltage and for ECM memory)
Always 11 to 14 V
C78-61 (LIN) - Body ground G - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher