The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during mass air flow meter sub-assembly removal/installation are shown below.
| Replaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
| Replacement of mass air flow meter sub-assembly | Inspection after repair | ·
Poor idle, etc. ·
Engine start function, etc. |
( 201906,999999,_51,_080777,_0393969,RM100000001I1RE,)
|
22204
1.REMOVE MASS AIR FLOW METER SUB-ASSEMBLY
Disengage the clamp and disconnect the mass air flow meter sub-assembly connector.
Remove the 2 screws and mass air flow meter sub-assembly from the air cleaner cap sub-assembly.
If the mass air flow meter sub-assembly has been struck or dropped, replace it.