84970
1.INSPECT COMBINATION SWITCH ASSEMBLY
| *a | Component without harness connected
(Combination Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (MSW1) - 5 (E) | Pressed | Below 50 Ω |
| Not pressed | 10 kΩ or higher |
If the result is not as specified, replace the combination switch assembly.
| *a | Component without harness connected
(Combination Switch Assembly) |
Apply battery voltage between the terminals of the switch and check the illumination condition of the combination switch assembly.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (ILL+)
Battery negative (-) → 1 (ILL-) |
Illuminates |
If the result is not as specified, replace the combination switch assembly.