| Item | Specified Condition |
|---|---|
| Standard Value (for Brand-new Cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum Standard Value (for Used Cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
| IGCT relay (IGCT)
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
| SMRB
Resistance |
z22-1 (+) - W3-1 (CBI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-4 (SMRB) and O169-2 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals O169-4 (SMRB) and O169-2 (GND) |
||
| O169-4 (SMRB) - O169-2 (GND) | 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG
Resistance |
z23-1 (-) - W2-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-6 (SMRG) and O169-2 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals O169-6 (SMRG) and O169-2 (GND) |
||
| O169-6 (SMRG) - O169-2 (GND) | 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F) |
| SMRB
Resistance |
z22-1 (+) - W3-1 (CBI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-4 (SMRB) and O169-2 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals O169-4 (SMRB) and O169-2 (GND) |
||
| O169-4 (SMRB) - O169-2 (GND) | 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG
Resistance |
z23-1 (-) - W2-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-6 (SMRG) and O169-2 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals O169-6 (SMRG) and O169-2 (GND) |
||
| O169-6 (SMRG) - O169-2 (GND) | 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F) |
| EV Drive Mode Switch (Combination Switch Assembly)
Resistance |
I61-8 (S) - I61-5 (E) | Below 50 Ω
(EV drive mode switch (combination switch assembly) being pushed and held) |
| 10 kΩ or higher
(EV drive mode switch (combination switch assembly) not pushed) |
||
| Auxiliary Battery positive (+) → I61-4 (ILL+)
Auxiliary Battery negative (-) → I61-1 (ILL-) |
Illuminates |
| Drive Mode Select Switch (Combination Switch Assembly)
Resistance |
I61-6 (DRV) - I61-5 (E) | Below 50 Ω
(Drive mode select switch (combination switch assembly) being pushed and held) |
| 10 kΩ or higher
(Drive mode select switch (combination switch assembly) not pushed) |
||
| Auxiliary Battery positive (+) → I61-4 (ILL+)
Auxiliary Battery negative (-) → I61-1 (ILL-) |
Illuminates |
| Service Plug Grip | - | Below 1 Ω |