RM3660EC _V1 General _080738 SPECIFICATIONS _0391445 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT relay (IGCT)
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)

HV Battery Junction Block Assembly (for 8ZR-FXE)
SMRB
Resistance
z22-1 (+) - W3-1 (CBI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-4 (SMRB) and O169-2 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals O169-4 (SMRB) and O169-2 (GND)
O169-4 (SMRB) - O169-2 (GND) 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
z23-1 (-) - W2-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-6 (SMRG) and O169-2 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals O169-6 (SMRG) and O169-2 (GND)
O169-6 (SMRG) - O169-2 (GND) 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F)

HV Battery Junction Block Assembly (for M20F-FXS, M20G-FXS)
SMRB
Resistance
z22-1 (+) - W3-1 (CBI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-4 (SMRB) and O169-2 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals O169-4 (SMRB) and O169-2 (GND)
O169-4 (SMRB) - O169-2 (GND) 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
z23-1 (-) - W2-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals O169-6 (SMRG) and O169-2 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals O169-6 (SMRG) and O169-2 (GND)
O169-6 (SMRG) - O169-2 (GND) 20.6 to 40.8 Ω at -40 to 80°C (-40 to 176°F)

EV Drive Mode Switch (Combination Switch Assembly)
EV Drive Mode Switch (Combination Switch Assembly)
Resistance
I61-8 (S) - I61-5 (E) Below 50 Ω
(EV drive mode switch (combination switch assembly) being pushed and held)
10 kΩ or higher
(EV drive mode switch (combination switch assembly) not pushed)
Auxiliary Battery positive (+) → I61-4 (ILL+)
Auxiliary Battery negative (-) → I61-1 (ILL-)
Illuminates

Drive Mode Select Switch (Combination Switch Assembly)
Drive Mode Select Switch (Combination Switch Assembly)
Resistance
I61-6 (DRV) - I61-5 (E) Below 50 Ω
(Drive mode select switch (combination switch assembly) being pushed and held)
10 kΩ or higher
(Drive mode select switch (combination switch assembly) not pushed)
Auxiliary Battery positive (+) → I61-4 (ILL+)
Auxiliary Battery negative (-) → I61-1 (ILL-)
Illuminates

Service Plug Grip
Service Plug Grip - Below 1 Ω