SPECIFICATIONS
_0391427
8ZR-FXE COOLING
F
SPECIFICATIONS 8ZR-FXE COOLING SERVICE DATA
Thermostat
| Compression Spring Shape
|
Condition
|
Specified Condition
|
| Tapered
|
Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)
|
| Straight
|
Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
8 mm (0.315 in.) or more at 95°C (203°F)
|
Cooling Fan Motor
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor LH
|
Auxiliary battery voltage applied at 20°C (68°F)
|
7.4 to 10.9 A
|
| Cooling fan motor RH
|
7.4 to 10.9 A
|
Radiator
| Item
|
Condition
|
Specified Condition
|
| Radiator cap sub-assembly
|
Standard pressure
(for radiator cap sub-assembly)
|
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi)
|
Minimum pressure
(for used radiator cap sub-assembly)
|
59 kPa (0.6 kgf/cm2, 8.6 psi)
|
Relay
| Item
|
Tester Connection
|
Condition
|
Specified Condition
|
| FAN NO. 1 relay
|
3 - 5
|
Auxiliary battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary batteryBattery voltage applied between terminals 1 and 2
|
Below 1 Ω
|
| FAN NO. 2 relay
|
3 - 4
|
Auxiliary battery voltage not applied between terminals 1 and 2
|
Below 1 Ω
|
| Auxiliary battery voltage applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 5
|
Auxiliary battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|
| FAN NO. 3 relay
|
3 - 5
|
Auxiliary battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|