If cool air is not discharged (air is discharged), the following malfunctions are possible.
| Malfunction Status | Factor |
|---|---|
| Cool air is not discharged (air is discharged) | ·
Compressor with motor assembly malfunction ·
Refrigerant pressure malfunction ·
Lack of refrigerant gas ·
Dirty cooler condenser ·
Cooling fan system malfunction ·
Air mix damper and link operation (jamming) ·
Evaporator temperature sensor (determined as cold, but conflicts with actual temperature) ·
Warm air flow |
Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
All switch indicators operate normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Air Mix Damper Control Motor (Potentio) | This test activates the front air mix damper control motor (potentio).
(No. 3 air conditioning radiator damper servo sub-assembly) |
0 %: Min
100 %: Max |
Operate with the ignition switch ON. |
| Active Test Display |
|---|
| Front Air Mix Damper Control Motor (Potentio) |
| Data List Display |
|---|
| Front Air Mix Damper Control Motor Actual Opening (Potentio) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG