HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model (8ZR-FXE))  B141A11  Room Temperature Sensor Circuit Short to Ground  


DESCRIPTION

The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B141A11 Room Temperature Sensor Circuit Short to Ground Diagnosis Condition:

Ignition switch ON


Malfunction:

Short (GND) in room temperature sensor circuit


Detection Time:

Continuously for 4 seconds or more


·

Room temp. sensor (cooler thermistor)

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized

WIRING DIAGRAM

E546056E35
0.198,1.802 0.531,2 0.333,0.198 10 false I36 0.188,1.979 2.677,2.167 2.49,0.188 10 false Room Temp. Sensor (Cooler Thermistor) 4.635,1.792 6.938,2.073 2.302,0.281 10 false Air Conditioning Amplifier Assembly 2.146,0.667 2.323,0.885 0.177,0.219 10 false 1 2.156,1.156 2.333,1.375 0.177,0.219 10 false 2 4.458,1.073 4.688,1.292 0.229,0.219 10 false 23 4.49,0.573 4.677,0.76 0.188,0.188 10 false 4 4.823,0.781 5.073,0.969 0.25,0.188 10 false TR 4.813,1.26 5.219,1.448 0.406,0.188 10 false SG-1 4.438,0.792 4.771,0.99 0.333,0.198 10 false I49 4.438,1.26 4.771,1.458 0.333,0.198 10 false I49

PROCEDURE

1.CLEAR DTC
a.

Clear the DTCs.

Body Electrical > Air Conditioner > Clear DTCs
50002 450

Result:
Proceed to
NEXT



NEXT

2.CHECK FOR DTC
2.CHECK FOR DTC
a.

Turn the ignition switch off.


b.
E478812C26
0.917,1.771 1.281,2 0.365,0.229 10 false *1 2.667,1.771 3.031,2 0.365,0.229 10 false *2 2.042,0.646 2.5,0.917 0.458,0.271 10 false TR 1.896,1 2.417,1.24 0.521,0.24 10 false SG-1
*1 Room Temp. Sensor (Cooler Thermistor)
*2 Air Conditioning Amplifier Assembly


Disconnect the room temp. sensor (cooler thermistor) connector.


c.

Turn the ignition switch to ON and wait for 4 seconds or more.


d.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 450
Result:
Result Proceed to
B141A15 is output A
B141A11 is output B




A

B

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
a.

Disconnect the I36 room temp. sensor (cooler thermistor) connector.


b.

Disconnect the I49 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I36-1 or I49-4 (TR) - Other terminals and body ground Always 10 kΩ or higher
I36-2 or I49-23 (SG-1) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR