RM3660EC _57 Power Source / Network _080757 8ZR-FXE BATTERY / CHARGING _0393175 CHARGING SYSTEM D

8ZR-FXE BATTERY / CHARGING  CHARGING SYSTEM  DIAGNOSIS SYSTEM  



AUXILIARY BATTERY VOLTAGE


Standard Voltage:
Switch Condition Specified Condition
Power switch on (IG) 11 to 14 V


If voltage is below 11 V, recharge or replace the auxiliary battery.

NOTICE:
·

After the power switch off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

Make sure to perform the necessary procedures (adjustment, calibration, initialization, or registration) after parts related to the charging system have been removed/installed or replaced.

Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE

·

When disconnecting and reconnecting the auxiliary battery.

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART