RM3660EC
_V1
General
_080738
SPECIFICATIONS
_0391422
8ZR-FXE ENGINE CONTROL
F
SPECIFICATIONS 8ZR-FXE ENGINE CONTROL SERVICE DATA
IGNITION SYSTEM
| Standard Insulation Resistance
|
Spark plug (terminal part) - Body ground
|
10 MΩ or higher
|
| Spark Plug Type
|
DENSO made
|
FC16HR-CY9
|
| Maximum Electrode Gap
|
for Used Spark Plug
|
1.1 mm (0.0433 in.)
|
| Standard Electrode Gap
|
for New Spark Plug
|
0.8 to 0.9 mm (0.0315 to 0.0354 in.)
|
CAMSHAFT OIL CONTROL VALVE
| Standard Resistance
|
20°C (68°F)
|
6.9 to 7.9 Ω
|
THROTTLE BODY
| Standard Resistance
|
1 (M-) - 2 (M+)
|
20°C (68°F)
|
0.3 to 100 Ω
|
ENGINE COOLANT TEMPERATURE SENSOR
| Standard Resistance
|
20°C (68°F)
|
2.32 to 2.59 kΩ
|
| 80°C (176°F)
|
0.310 to 0.326 kΩ
|
KNOCK SENSOR
| Standard Resistance
|
25°C (77°F)
|
120 to 280 kΩ
|
AIR FUEL RATIO SENSOR
| Standard Resistance
|
1 (HA1A) - 2 (+B)
|
20°C (68°F)
|
1.4 to 3.0 Ω
|
| 1 (HA1A) - 4 (A1A-)
|
Always
|
10 kΩ or higher
|
HEATED OXYGEN SENSOR
| Standard Resistance
|
1 (HT1B) - 2 (+B)
|
20°C (68°F)
|
5 to 10 Ω
|
| 1 (HT1B) - 4 (E2)
|
Always
|
10 kΩ or higher
|
RELAY
Standard Resistance
(Circuit Opening Relay Assembly (C/OPN))
|
3 - 5
|
Auxiliary battery voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage is applied between terminals 1 and 2
|
Below 1 Ω
|
Standard Resistance
(No. 1 Electronic Fuel Injection Main Relay (EFI-MAIN NO.1))
|
3 - 5
|
Auxiliary battery voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage is applied between terminals 1 and 2
|
Below 1 Ω
|
Standard Resistance
(No. 2 Electronic Fuel Injection Main Relay (EFI-MAIN NO.2))
|
3 - 5
|
Auxiliary battery voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage is applied between terminals 1 and 2
|
Below 1 Ω
|
Standard Resistance
(No. 3 Electronic Fuel Injection Main Relay (EFI-MAIN NO.3))
|
3 - 5
|
Auxiliary battery voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage is applied between terminals 1 and 2
|
Below 1 Ω
|
Standard Resistance
(IGP Relay (IGP-MAIN))
|
3 - 5
|
Auxiliary battery voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage is applied between terminals 1 and 2
|
Below 1 Ω
|