RM35X0E _V1 General _080617 SPECIFICATIONS _0393135 DOOR LOCK F

SPECIFICATIONS  DOOR LOCK  SERVICE DATA  


UN-LOCK WARNING SWITCH ASSEMBLY:
Resistance 1 (UN+) - 2 (UN-) Switch not pushed (Key removed) 10 kΩ or higher
Switch pushed (Key inserted) Below 1 Ω


FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH:
Resistance 7 (E) - 8 (LSSR) Locked 10 kΩ or higher
Unlocked Below 1 Ω
9 (L) - 7 (E) Lock Below 1 Ω
Neutral 10 kΩ or higher
10 (UL) - 7 (E) Lock Below 1 Ω
Neutral 10 kΩ or higher


FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH:
Resistance 7 (LSSR) - 8 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω
6 (L) - 8 (E) Lock Below 1 Ω
Neutral 10 kΩ or higher
5 (UL) - 8 (E) Unlock Below 1 Ω
Neutral 10 kΩ or higher


BACK DOOR LOCK ASSEMBLY WITH COURTESY LIGHT SWITCH (except Double Swing Out Type, w/o Easy Closer):
Resistance 1 - 2 Back Door Closed (Locked) 10 kΩ or higher
Back Door Opened (Unlocked) Below 1 Ω


BACK DOOR LOCK ASSEMBLY WITH COURTESY LIGHT SWITCH (for Double Swing Out Type):
Resistance 1 - 2 Back Door Closed (Locked) 10 kΩ or higher
Back Door Opened (Unlocked) Below 1 Ω


BACK DOOR LOCK ASSEMBLY WITH COURTESY LIGHT SWITCH (w/ Easy Closer):
Resistance 2 (CLS) - 6 (E) Open-latch Position → Half-latch position Below 1 Ω → 10 kΩ or higher
Half-latch position → Full-latch Position 10 kΩ or higher
Full-latch Position 10 kΩ or higher
3 (CTY) - 6 (E) Open-latch Position Below 1 Ω
Half-latch position → Full-latch Position Below 1 Ω → 10 kΩ or higher
Full-latch Position 10 kΩ or higher
5 (OPN) - 6 (E) Open-latch Position → Half-latch position 10 kΩ or higher → Below 1 Ω
Half-latch position → Full-latch Position Below 1 Ω
Full-latch Position Below 1 Ω


BACK DOOR REMOTE CONTROL ASSEMBLY (except Double Swing Out Type):
Resistance 1 (S) - 4 (E) Lock 10 kΩ or higher
Unlock Below 1 Ω


BACK DOOR REMOTE CONTROL ASSEMBLY (for Double Swing Out Type):
Resistance 1 (S) - 4 (E) Lock 10 kΩ or higher
Unlock Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY LH (w/ Power Slide Door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) Below 1 Ω
Neutral position 10 kΩ or higher
1 (DS1) - 3 (GND) Handle pulled (close side) Below 1 Ω
Neutral position 10 kΩ or higher
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY LH (except Wagon, w/o Power Slide Door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) 10 kΩ or higher
Neutral position Below 1 Ω
1 (DS1) - 3 (GND) Handle pulled (close side) 10 kΩ or higher
Neutral position Below 1 Ω
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY LH (for Wagon, w/o Power Slide Door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) 10 kΩ or higher
Neutral position Below 1 Ω
2 (DS2) - 3 (GND) Handle pulled (close side) 10 kΩ or higher
Neutral position Below 1 Ω
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH (w/ Power Slide door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) Below 1 Ω
Neutral position 10 kΩ or higher
1 (DS1) - 3 (GND) Handle pulled (close side) Below 1 Ω
Neutral position 10 kΩ or higher
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH (except Wagon, w/o Power Slide door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) 10 kΩ or higher
Neutral position Below 1 Ω
1 (DS1) - 3 (GND) Handle pulled (close side) 10 kΩ or higher
Neutral position Below 1 Ω
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH (for Wagon, w/o Power Slide door):
Resistance 2 (DS2) - 3 (GND) Handle pulled (open side) 10 kΩ or higher
Neutral position Below 1 Ω
2 (DS2) - 3 (GND) Handle pulled (close side) 10 kΩ or higher
Neutral position Below 1 Ω
4 (LSSR) - 1 (E) Locked 10 kΩ or higher
Unlocked Below 1 Ω


POWER SLIDE DOOR LOCK ASSEMBLY LH (w/ Power Slide Door):
Resistance 7 (E1) - 9 (NPC) Neutral position
(neutral release switch)
10 kΩ or higher
Neutral position
(neutral close switch)
10 kΩ or higher
Active lever is moved in direction of release operation 10 kΩ or higher
Active lever is moved in direction of close operation Below 1 Ω
7 (E1) - 8 (NPR) Neutral position
(neutral release switch)
Below 1 Ω
Neutral position
(neutral close switch)
10 kΩ or higher
Active lever is moved in direction of release operation Below 1 Ω
Active lever is moved in direction of close operation 10 kΩ or higher
5 (HAF) - 7 (E1) Open-latch Below 1 Ω
Half-latch 10 kΩ or higher
Full-latch 10 kΩ or higher
6 (FUL) - 7 (E1) Open-latch Below 1 Ω
Half-latch Below 1 Ω
Full-latch 10 kΩ or higher
10 (POL) - 7 (E1) Open-latch Below 1 Ω
Half-latch 10 kΩ or higher
Between half-latch and full-latch 10 kΩ or higher → Below 1 Ω
Full-latch 10 kΩ or higher


POWER SLIDE DOOR LOCK ASSEMBLY RH (w/ Power Slide Door):
Resistance 7 (E1) - 9 (NPC) Neutral position
(neutral release switch)
10 kΩ or higher
Neutral position
(neutral close switch)
10 kΩ or higher
Active lever is moved in direction of release operation 10 kΩ or higher
Active lever is moved in direction of close operation Below 1 Ω
7 (E1) - 8 (NPR) Neutral position
(neutral release switch)
Below 1 Ω
Neutral position
(neutral close switch)
10 kΩ or higher
Active lever is moved in direction of release operation Below 1 Ω
Active lever is moved in direction of close operation 10 kΩ or higher
5 (HAF) - 7 (E1) Open-latch Below 1 Ω
Half-latch 10 kΩ or higher
Full-latch 10 kΩ or higher
6 (FUL) - 7 (E1) Open-latch Below 1 Ω
Half-latch Below 1 Ω
Full-latch 10 kΩ or higher
10 (POL) - 7 (E1) Open-latch Below 1 Ω
Half-latch 10 kΩ or higher
Between half-latch and full-latch 10 kΩ or higher → Below 1 Ω
Full-latch 10 kΩ or higher


SLIDE DOOR CONTROL JUNCTION MALE (for LH Side):
TYPE A
Resistance A-1 (L) - V15-2 (L) Always Below 1 Ω
A-5 (UL) - V15-4 (UL)


SLIDE DOOR CONTROL JUNCTION MALE (for LH Side):
TYPE B
Resistance A-1 (L) - V15-2 (L) Always Below 1 Ω
A-2 (LSSR) - V15-3 (LSSR)
A-3 (E) - V15-5 (E)
A-5 (UL) - V15-4 (UL)


SLIDE DOOR CONTROL JUNCTION MALE (for RH Side):
TYPE A
Resistance A-1 (UL) - W13-4 (UL) Always Below 1 Ω
A-5 (L) - W13-2 (L)


SLIDE DOOR CONTROL JUNCTION MALE (for RH Side):
TYPE B
Resistance A-1 (UL) - W13-4 (UL) Always Below 1 Ω
A-3 (E) - W13-5 (E)
A-4 (LSSR) - W13-3 (LSSR)
A-5 (L) - W13-2 (L)


SLIDE DOOR CONTROL JUNCTION FEMALE:
TYPE A
Resistance A-1 (L) - B-1 (L) Always Below 1 Ω
A-5 (UL) - B-2 (UL)


SLIDE DOOR CONTROL JUNCTION FEMALE:
TYPE B
Resistance A-1 (L) - B-2 (L) Always Below 1 Ω
A-2 (DLSE) - B-1 (DLSE)
A-3 (E) - B-4 (E)
A-5 (UL) - B-3 (UL)