84922
1.INSPECT FRONT POWER SEAT SWITCH (for LHD)
| *a | Slide and Front Vertical Switch |
| *b | Slide and Lifter Switch |
| *c | Reclining Switch |
| *d | Component without harness connected
(Front Power Seat Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| n9-4 (SLDF) - n9-6 (B) | Front position | Below 1 Ω |
| n9-1 (SLDR) - n9-12 (E) | ||
| n9-4 (SLDF) - n9-12 (E) | Neutral | Below 1 Ω |
| n9-1 (SLDR) - n9-12 (E) | ||
| n9-4 (SLDF) - n9-12 (E) | Rear position | Below 1 Ω |
| n9-1 (SLDR) - n9-6 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| n9-7 (FUP) - n9-6 (B) | Up position | Below 1 Ω |
| n9-11 (FDWN) - n9-12 (E) | ||
| n9-7 (FUP) - n9-12 (E) | Neutral | Below 1 Ω |
| n9-11 (FDWN) - n9-12 (E) | ||
| n9-7 (FUP) - n9-12 (E) | Down position | Below 1 Ω |
| n9-11 (FDWN) - n9-6 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| n9-8 (RUP) - n9-6 (B) | Up position | Below 1 Ω |
| n9-10 (RDWN) - n9-12 (E) | ||
| n9-8 (RUP) - n9-12 (E) | Neutral | Below 1 Ω |
| n9-10 (RDWN) - n9-12 (E) | ||
| n9-8 (RUP) - n9-12 (E) | Down position | Below 1 Ω |
| n9-10 (RDWN) - n9-6 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| n9-5 (RCLF) - n9-6 (B) | Front position | Below 1 Ω |
| n9-3 (RCLR) - n9-12 (E) | ||
| n9-5 (RCLF) - n9-12 (E) | Neutral | Below 1 Ω |
| n9-3 (RCLR) - n9-12 (E) | ||
| n9-5 (RCLF) - n9-12 (E) | Rear position | Below 1 Ω |
| n9-3 (RCLR) - n9-6 (B) |
If the result is not as specified, replace the front power seat switch.
84922
2.INSPECT FRONT POWER SEAT SWITCH (for RHD)
| *a | Slide and Front Vertical Switch |
| *b | Slide and Lifter Switch |
| *c | Reclining Switch |
| *d | Lumbar Support Switch (w/ Lumbar Support) |
| *e | Component without harness connected
(Front Power Seat Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| m9-2 (SLDF) - m9-12 (B) | Front position | Below 1 Ω |
| m9-5 (SLDR) - m9-6 (E) | ||
| m9-2 (SLDF) - m9-6 (E) | Neutral | Below 1 Ω |
| m9-5 (SLDR) - m9-6 (E) | ||
| m9-2 (SLDF) - m9-6 (E) | Rear position | Below 1 Ω |
| m9-5 (SLDR) - m9-12 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| m9-11 (FUP) - m9-12 (B) | Up position | Below 1 Ω |
| m9-7 (FDWN) - m9-6 (E) | ||
| m9-11 (FUP) - m9-6 (E) | Neutral | Below 1 Ω |
| m9-7 (FDWN) - m9-6 (E) | ||
| m9-11 (FUP) - m9-6 (E) | Down position | Below 1 Ω |
| m9-7 (FDWN) - m9-12 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| m9-10 (RUP) - m9-12 (B) | Up position | Below 1 Ω |
| m9-8 (RDWN) - m9-6 (E) | ||
| m9-10 (RUP) - m9-6 (E) | Neutral | Below 1 Ω |
| m9-8 (RDWN) - m9-6 (E) | ||
| m9-10 (RUP) - m9-6 (E) | Down position | Below 1 Ω |
| m9-8 (RDWN) - m9-12 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| m9-1 (RCLF) - m9-12 (B) | Front position | Below 1 Ω |
| m9-3 (RCLR) - m9-6 (E) | ||
| m9-1 (RCLF) - m9-6 (E) | Neutral | Below 1 Ω |
| m9-3 (RCLR) - m9-6 (E) | ||
| m9-1 (RCLF) - m9-6 (E) | Rear position | Below 1 Ω |
| m9-3 (RCLR) - m9-12 (B) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| m9-9 (H) - m9-12 (B) | Hold position | Below 1 Ω |
| m9-4 (R) - m9-6 (E) | ||
| m9-9 (H) - m9-6 (E) | Neutral | Below 1 Ω |
| m9-4 (R) - m9-6 (E) | ||
| m9-9 (H) - m9-6 (E) | Release position | Below 1 Ω |
| m9-4 (R) - m9-12 (B) |
If the result is not as specified, replace the front power seat switch.