79335B
1.INSPECT NO. 3 SEAT CUSHION PAD RH (OCCUPANT DETECTION SENSOR)
for RH:
| *a | Component without harness connected
(No. 3 Seat Cushion Pad RH (occupant detection sensor)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
If the result is not as specified, replace the No. 3 seat cushion pad RH (occupant detection sensor). |
||
| 1 - 3 | RH seat occupied | Below 100 Ω |
| RH seat not occupied | 1 MΩ or higher | |
for CENTER:
| *a | Component without harness connected
(No. 3 Seat Cushion Pad RH (occupant detection sensor)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
If the result is not as specified, replace the No. 3 seat cushion pad RH (occupant detection sensor). |
||
| 1 - 2 | Center seat occupied | Below 100 Ω |
| Center seat not occupied | 1 MΩ or higher | |