RM35X0E
_V1
General
_080617
SPECIFICATIONS
_0391332
HEATING / AIR CONDITIONING
F
SPECIFICATIONS HEATING / AIR CONDITIONING SERVICE DATA
REFRIGERANT:
| Refrigerant charge volume
|
w/o Rear Cooler
|
620 to 720 g (21.9 to 25.3 oz)
|
| w/ Rear Cooler, Condenser Type A
|
700 to 800 g (24.7 to 28.2 oz)
|
| w/ Rear Cooler, Condenser Type B, for 7GR-FKS
|
870 to 930 g (30.7 to 32.8 oz)
|
| w/ Rear Cooler, Condenser Type B, for 1GD-FTV
|
770 to 870 g (27.2 to 30.6 oz)
|
| w/ Rear Air Conditioning, for 7GR-FKS
|
950 to 1050 g (33.6 to 37.0 oz)
|
| w/ Rear Air Conditioning, for 1GD-FTV
|
900 to 1000 g (31.8 to 35.2 oz)
|
REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY
| Measurement Condition
|
Condition
|
Specified Condition
|
| 1 - 2
|
Rear blower with fan motor sub-assembly operate
|
Below 1.8 A
|
BLOWER RESISTOR (for Rear Heater)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (HI) - 2 (M1)
|
Always
|
0.36 to 0.42 Ω
|
| 1 (HI) - 3 (M2)
|
Always
|
1.39 to 1.59 Ω
|
| 1 (HI) - 4 (LO)
|
Always
|
2.59 to 2.99 Ω
|
REAR COOLING UNIT BLOWER MOTOR RESISTOR LH
| Tester Connection
|
Condition
|
Specified Condition
|
| 4 (HI) - 2 (M2)
|
Always
|
0.20 to 0.24 Ω
|
| 4 (HI) - 3 (M1)
|
Always
|
0.64 to 0.73 Ω
|
| 4 (HI) - 1 (E)
|
Always
|
1.22 to 1.40 Ω
|
REAR COOLING UNIT BLOWER MOTOR RESISTOR RH
| Tester Connection
|
Condition
|
Specified Condition
|
| 4 (HI) - 2 (M2)
|
Always
|
0.20 to 0.24 Ω
|
BLOWER RESISTOR (for LHD)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (HI) - 3 (M2)
|
Always
|
0.39 to 0.45 Ω
|
| 1 (HI) - 2 (M1)
|
Always
|
1.32 to 1.52 Ω
|
| 1 (HI) - 4 (E)
|
Always
|
2.08 to 2.40 Ω
|
BLOWER RESISTOR (for RHD)
| Tester Connection
|
Condition
|
Specified Condition
|
| 4 (HI) - 2 (M2)
|
Always
|
0.39 to 0.45 Ω
|
| 4 (HI) - 3 (M1)
|
Always
|
1.32 to 1.52 Ω
|
| 4 (HI) - 1 (E)
|
Always
|
2.08 to 2.40 Ω
|
SOLAR SENSOR ASSEMBLY
| Tester Connection
|
Condition
|
Specified Condition
|
| Q5-1 (SE) - Q5-2 (NSHA)
|
Sensor is subjected to electric light
|
0.8 to 4.3 V
|
| Q5-1 (SE) - Q5-2 (NSHA)
|
Sensor is covered with a cloth
|
Below 0.8 V
|
MAGNET VALVE
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (RMGV) - 2 (IG+)
|
20°C (68°F)
|
20.5 to 26.5 Ω
|
REAR AIR CONDITIONING UNIT
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (RMGV) - 2 (IG+)
|
20°C (68°F)
|
20.5 to 26.5 Ω
|