RM35X0E _58 Vehicle Interior _079316 HEATING / AIR CONDITIONING _0386651 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Data List.


ii.

for Engine: Powertrain / Engine / Data List (except 1GD-FTV (w/ Exhaust Gas Temperature Sensor for EGR)).


iii.

for Engine and Transmission: Powertrain / Engine and Transmission / Data List (for 1GD-FTV (w/ Exhaust Gas Temperature Sensor for EGR)).



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler thermistor (room temperature sensor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler thermistor (room temperature sensor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Thermistor assembly (ambient temperature sensor) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly (ambient temperature sensor) circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -30.00°C (-22.00°F)
Max.: 59.60°C (139.28°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -30.00°C (-22.00°F)

·

When short circuit: 59.60°C (139.28°F)


Evaporator Target Temp Evaporator target temperature Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Evaporator target temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Solar Sensor (D Side) Automatic light control sensor Min.: 0
Max.: 255
Automatic light control sensor value increases as brightness increases Automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

SFI system malfunction (for 7GR-FKS)

·

ECD system malfunction (for 1GD-FTV)

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower with fan motor sub-assembly circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG (gauge)
Max.: 3.2943 MPaG (gauge)
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak, etc.)

·

Air conditioner pressure sensor circuit malfunction


Room Temp Sensor (Rear) Cooler thermistor (No. 2 room temperature sensor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler thermistor (No. 2 room temperature sensor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Evap Temp Sensor (Rear) No. 2 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 2 Cooler thermistor circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Blower Motor Level (Rear) Rear blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases between 0 and 31 as rear blower motor speed increases Rear blower with fan motor sub-assembly system malfunction
Air Outlet Servo Pulse (R) No. 2 rear cooling unit damper servo sub-assembly (rear mode) target pulse Min.: 128
Max.: 383
·

FACE: 276 (pulse)

·

B/L: 238 (pulse)

·

FOOT: 200 (pulse)


No. 2 rear cooling unit damper servo sub-assembly (rear mode) circuit malfunction
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Air Outlet Servo Actual Pls(R) No. 2 rear cooling unit damper servo sub-assembly (rear mode) actual pulse Min.: 128
Max.: 383
·

FACE: 276 (pulse)

·

B/L: 238 (pulse)

·

FOOT: 200 (pulse)


No. 2 rear cooling unit damper servo sub-assembly (rear mode) circuit malfunction
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Air Mix Servo Targ Pulse(R) No. 1 rear cooling unit damper servo sub-assembly (rear air mix) target pulse Min.: 128
Max.: 383
·

MAX. COLD: 254 (pulse)

·

MAX. HOT: 299 (pulse)


No. 1 rear cooling unit damper servo sub-assembly (rear air mix) circuit malfunction
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Air Mix Servo Actual Pulse(R) No. 1 rear cooling unit damper servo sub-assembly (rear air mix) actual pulse Min.: 128
Max.: 383
·

MAX. COLD: 254 (pulse)

·

MAX. HOT: 299 (pulse)


No. 1 rear cooling unit damper servo sub-assembly (rear air mix) circuit malfunction
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse Min.: 128
Max.: 383
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-R (F): 305 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

DEF: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse Min.: 128
Max.: 383
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-R (F): 305 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

DEF: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
for 1 Layer Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


for 2 Layer Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for 1 Layer Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


for 2 Layer Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Electric Heater Count Maximum PTC heater operation level Min.: 0
Max.: 3
Maximum possible operation of PTC heater displayed (w/ PTC Heater)
Electric Heater Active Level Number of electric heaters operating Min.: 0
Max.: 3
Actual operation level of PTC heater displayed (w/ PTC Heater)
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr or 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
ECO MODE Cancel Function to cancel ECO driver mode when set to ON OFF or ON Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal or Fast Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
IDLE UP/PWR HEAT Switch Idle up switch (w/ Idle Up Switch)
Heater switch assembly (w/ Viscous Heater)
ON or OFF
w/ Idle Up Switch:

ON: Idle up switch on

OFF: Idle up switch off


w/ Viscous Heater:

ON: Heater switch assembly on

OFF: Heater switch assembly off


(w/ Idle Up Switch)
(w/ Viscous Heater)
Ion Generate Control Ion generator control ON or OFF Customized value displayed (w/ Ion Generator)
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Front side set temperature Min.: MAX COLD
Max.: MAX HOT
Set temperature displayed -
Set Temperature (Rear) Rear side set temperature Min.: MAX COLD
Max.: MAX HOT
Set temperature displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).



Powertrain > Engine and Transmission > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Active Test.


ii.

for Engine: Powertrain / Engine / Active Test.



e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Magnetic Clutch Relay Magnet-clutch relay OFF/ON -
Electrical Fan Condenser fan OFF/ON (w/ Condenser Fan)
Heater Active Level Quick heater assembly Min.: 0
Max.: 3
(w/ PTC Heater)
Air Mix Servo Targ Pulse(D)

No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse


Min.: 128
Max.: 383
Operates between 165 to 257 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse Min.: 128
Max.: 383
Operates between 256 to 348 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
for 1 Layer Type:

Operates between 235 to 258 pulses


for 2 Layer Type:

Operates between 220 to 256 pulses


Rear Blower Motor Rear blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Rear Air Mix Servo Targ Pulse No. 1 rear cooling unit damper servo motor sub-assembly (rear air mix) pulse Min.: 128
Max.: 383
Operates between 254 and 299 pulses
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Rear A/C Mag Valve Cooler expansion valve OFF/ON (w/ Integration Control Panel)
Viscous Heater Viscous heater magnet clutch relay OFF/ON (w/ Viscous Heater)
A/O Servo Pulse(Rr D) No. 2 rear cooling unit damper servo motor sub-assembly (rear mode) pulse Min.: 128
Max.: 383
Operates between 200 and 276 pulses
(w/ Integration Control Panel (for Rear Automatic Air Conditioning))
Ion Generator Ion generator OFF/ON (w/ Ion Generator)