1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
88891Q
2.REMOVE NO. 2 COOLER COVER
Detach the clamp and disconnect the connector.
Remove the 3 screws.
Detach the guide and remove each No. 2 cooler cover from the air conditioner tube and accessory assembly.
88515A
3.REMOVE COOLER EXPANSION VALVE WITH MAGNET VALVE
Using a 4 mm hexagon socket wrench, remove the 2 bolts and cooler expansion valve with magnet valve.
Remove the 4 O-rings from the air conditioner tube and accessory.
Seal the openings of the disconnected parts using vinyl tape to prevent the entry of moisture and foreign matter.