RM35X0E _57 Power Source / Network _078664 7GR-FKS BATTERY / CHARGING _0387111 CHARGING SYSTEM U

7GR-FKS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


A356006E05
0.635,0.656 1,0.844 0.365,0.188 1.771,0.646 2.135,0.833 0.365,0.188 2.99,0.646 3.354,0.833 0.365,0.188 3.99,0.646 4.354,0.833 0.365,0.188 5.052,0.646 5.417,0.833 0.365,0.188 6.188,0.646 6.552,0.833 0.365,0.188 0.719,0.667 1.063,0.885 0.344,0.219 10 false E1 1.865,0.656 2.177,0.854 0.313,0.198 10 false E2 3.094,0.656 3.406,0.854 0.313,0.198 10 false E3 4.094,0.656 4.406,0.854 0.313,0.198 10 false E4 5.156,0.656 5.469,0.854 0.313,0.198 10 false N1 6.292,0.656 6.604,0.854 0.313,0.198 10 false A1

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage and resistance for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
E3-1 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A1-2 (BATT) - E3-1 (E1) B- W-B Battery
(for measuring battery voltage and for ECM memory)
Always 11 to 14 V
E1-34 (LIN) - Body ground P - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher