89341K
1.INSPECT FRONT CORNER ULTRASONIC SENSOR
| *a | Component without harness connected
(Front Corner Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
If the result is not as specified, replace the front corner ultrasonic sensor. |
||
| 1 (E) - 2 (S) | Always | 20 to 40 kΩ |