89467C
1.INSPECT AIR FUEL RATIO SENSOR (for Bank 1)
| *a | Component without harness connected
(Air Fuel Ratio Sensor) |
w/o Secondary Air Injection System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA1A) - 4 (A1A-) | Always | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.
| *a | Component without harness connected
(Air Fuel Ratio Sensor) |
w/ Secondary Air Injection System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA1A) - 4 (A1A-) | Always | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.
89467B
2.INSPECT AIR FUEL RATIO SENSOR (for Bank 2)
| *a | Component without harness connected
(Air Fuel Ratio Sensor) |
w/o Secondary Air Injection System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA2A) - 4 (A2A-) | Always | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.
| *a | Component without harness connected
(Air Fuel Ratio Sensor) |
w/ Secondary Air Injection System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA2A) - 4 (A2A-) | Always | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.