81240
1.INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Type A)
Check the room light.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
Apply battery voltage to the No. 1 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 3 (E) |
Room light switch on | Room light illuminates |
If the result is not as specified, replace the No. 1 room light assembly.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
Check the room light(for Door-linked).
Apply battery voltage to the No. 1 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 1 (CTY) |
Always | Room light illuminates |
If the result is not as specified, replace the No. 1 room light assembly.
81240
2.INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Type B)
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
Check the room light.
Apply battery voltage to the No. 1 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 1 (CTY) |
Always | Room light illuminates |
If the result is not as specified, replace the No. 1 room light assembly.
81240D
3.INSPECT NO. 2 ROOM LIGHT ASSEMBLY (for Type A)
Check the room light.
| *a | Component without harness connected
(No. 2 Room Light Assembly) |
Apply battery voltage to the No. 2 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 3 (CGON) |
Room light switch on | Room light illuminates |
If the result is not as specified, replace the No. 2 room light assembly.
| *a | Component without harness connected
(No. 2 Room Light Assembly) |
Check the room light(for Door-linked).
Apply battery voltage to the No. 2 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 1 (CCTY) |
Always | Room light illuminates |
If the result is not as specified, replace the No. 2 room light assembly.
81240D
4.INSPECT NO. 2 ROOM LIGHT ASSEMBLY (for Type B)
| *a | Component without harness connected
(No. 2 Room Light Assembly) |
Check the room light.
Apply battery voltage to the No. 2 room light assembly and check that the room light comes on.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 5 (B)
Battery negative (-) → 1 (CCTY) |
Always | Room light illuminates |
If the result is not as specified, replace the No. 2 room light assembly.