DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the following table, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Rear Left Door, Rear Right Door or Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PSD Touch Sensor | Power slide door sensor assembly LH signal | OFF, ON or Open | OFF: Power slide door sensor assembly LH not pressed
ON: Power slide door sensor assembly LH pressed Open: Power slide door sensor assembly LH open |
- |
| Handle Switch1 | Slide door lock remote control assembly LH (close switch) signal | ON or OFF | ON: Slide door inside handle or outside handle close operation performed (slide door lock remote control assembly LH [close switch] on)
OFF: Slide door inside handle or outside handle operation not performed or open operation performed (slide door lock remote control assembly LH [close switch] off) |
- |
| Handle Switch2 | Slide door lock remote control assembly LH (open switch) signal | ON or OFF | ON: Slide door inside handle or outside handle open operation performed (slide door lock remote control assembly LH [open switch] on)
OFF: Slide door inside handle or outside handle operation not performed or close operation performed (slide door lock remote control assembly LH [open switch] off) |
- |
| PSD Main Switch | Power slide door main switch signal | ON or OFF | ON: Power slide door main switch on
OFF: Power slide door main switch off |
- |
| Side Lifter | Limit switch state | ON or OFF | ON: Limit switch on
OFF: Limit switch off |
Not applicable |
| Door Sensor1 | Power slide door motor pulse sensor signal | ON or OFF | ON and OFF displayed alternately during power slide door operation | OFF displayed during power slide door not operation |
| Door Sensor2 | Power slide door motor pulse sensor signal | ON or OFF | ON and OFF displayed alternately during power slide door operation | OFF displayed during power slide door not operation |
| Power Voltage | Battery voltage | Min. 0, Max. 25.5 [V] | 11 to 14 [V] | - |
| Door Position | Slide door position | Min. 0, Max. 65535 [Pulse] | Current slide door position displayed | - |
| Status of PSD Sliding Motor | Power slide door motor condition | Stop, Opening or Closing | Power slide door motor condition displayed | - |
| Status of PSD Clutch | Power slide door clutch condition | ON or OFF | Power slide door clutch condition displayed | - |
| Status of PSD Buzzer | Power slide door buzzer condition | ON or OFF | Buzzer status displayed | - |
| Status of PSD Latch Operation | Slide door latch condition | Stop, Release or Close | Slide door latch condition displayed | - |
| Status of PSD Open Signal Output | Slide door full open signal output state | ON or OFF | ON: Slide door full open signal output (full open state)
OFF: Slide door full open signal not output (except full open state) |
Not applicable |
| PSD SW Operation | Slide door switch setting condition | 0.0 s or 0.8 s | Customization status displayed | - |
| PSD Buzz In Use | Power slide door warning buzzer setting condition | ON or OFF | Customization status displayed | - |
| Wireless PSD SW Operation | Wireless operation setting condition | OFF, 1Oper, 2Oper, long, 2/OM or L/OM | Customization status displayed | - |
| #Codes | Number of trouble codes | Min. 0, Max. 255 | Number of DTCs will be displayed | - |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PSD Touch Sensor | Power slide door sensor assembly RH signal | OFF, ON or Open | OFF: Power slide door sensor assembly RH not pressed
ON: Power slide door sensor assembly RH pressed Open: Power slide door sensor assembly RH open |
- |
| Handle Switch1 | Slide door lock remote control assembly RH (close switch) signal | ON or OFF | ON: Slide door inside handle or outside handle close operation performed (slide door lock remote control assembly RH [close switch] on)
OFF: Slide door inside handle or outside handle operation not performed or open operation performed (slide door lock remote control assembly RH [close switch] off) |
- |
| Handle Switch2 | Slide door lock remote control assembly RH (open switch) signal | ON or OFF | ON: Slide door inside handle or outside handle open operation performed (slide door lock remote control assembly RH [open switch] on)
OFF: Slide door inside handle or outside handle operation not performed or close operation performed (slide door lock remote control assembly RH [open switch] off) |
- |
| PSD Main Switch | Power slide door main switch signal | ON or OFF | ON: Power slide door main switch on
OFF: Power slide door main switch off |
- |
| Side Lifter | Limit switch state | ON or OFF | ON: Limit switch on
OFF: Limit switch off |
Not applicable |
| Door Sensor1 | Power slide door motor pulse sensor signal | ON or OFF | ON and OFF displayed alternately during power slide door operation | OFF displayed during power slide door not operation |
| Door Sensor2 | Power slide door motor pulse sensor signal | ON or OFF | ON and OFF displayed alternately during power slide door operation | OFF displayed during power slide door not operation |
| Power Voltage | Battery voltage | Min. 0, Max. 25.5 [V] | 11 to 14 [V] | - |
| Door Position | Slide door position | Min. 0, Max. 65535 [Pulse] | Current slide door position displayed | - |
| Status of PSD Sliding Motor | Power slide door motor condition | Stop, Opening or Closing | Power slide door motor condition displayed | - |
| Status of PSD Clutch | Power slide door clutch condition | ON or OFF | Power slide door clutch condition displayed | - |
| Status of PSD Buzzer | Power slide door buzzer condition | ON or OFF | Buzzer status displayed | - |
| Status of PSD Latch Operation | Slide door latch condition | Stop, Release or Close | Slide door latch condition displayed | - |
| Status of PSD Open Signal Output | Slide door full open signal output state | ON or OFF | ON: Slide door full open signal output (full open state)
OFF: Slide door full open signal not output (except full open state) |
Not applicable |
| PSD SW Operation | Slide door switch setting condition | 0.0 s or 0.8 s | Customization status displayed | - |
| PSD Buzz In Use | Power slide door warning buzzer setting condition | ON or OFF | Customization status displayed | - |
| Wireless PSD SW Operation | Wireless operation setting condition | OFF, 1Oper, 2Oper, long, 2/OM or L/OM | Customization status displayed | - |
| #Codes | Number of trouble codes | Min. 0, Max. 255 | Number of DTCs will be displayed | - |
| Tester Display | Measurement Item | Normal Condition | Reference Value | Diagnostic Note |
|---|---|---|---|---|
| Slide Door RH Close Switch | No. 1 power slide door control switch (slide door close switch RH) signal | ON or OFF | ON: No. 1 power slide door control switch (slide door close switch RH) on
OFF: No. 1 power slide door control switch (slide door close switch RH) off |
- |
| Slide Door LH Close Switch | No. 2 power slide door control switch (slide door close switch LH) signal | ON or OFF | ON: No. 2 power slide door control switch (slide door close switch LH) on
OFF: No. 2 power slide door control switch (slide door close switch LH) off |
- |
| Slide Door RH Open Switch | No. 1 power slide door control switch (slide door open switch RH) signal | ON or OFF | ON: No. 1 power slide door control switch (slide door open switch RH) on
OFF: No. 1 power slide door control switch (slide door open switch RH) off |
- |
| Slide Door LH Open Switch | No. 2 power slide door control switch (slide door open switch LH) signal | ON or OFF | ON: No. 2 power slide door control switch (slide door open switch LH) on
OFF: No. 2 power slide door control switch (slide door open switch LH) off |
- |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Rear Left Door or Rear Right Door / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| PSD Motor | Power slide door motor | OFF, Forward or Reverse | Power slide door control clutch is off while power slide door motor is operating |
| PSD Clutch | Power slide door control clutch | ON or OFF | Power slide door motor is off when clutch is on |
| PSD Buzzer | Power slide door warning buzzer | ON or OFF | - |
| PSD Open | Power slide door open | ON or OFF | - |
| PSD Open Signal | Slide door full open signal | OFF or ON | Not applicable |
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| PSD Motor | Power slide door motor | OFF, Forward or Reverse | Power slide door control clutch is off while power slide door motor is operating |
| PSD Clutch | Power slide door control clutch | ON or OFF | Power slide door motor is off when clutch is on |
| PSD Buzzer | Power slide door warning buzzer | ON or OFF | - |
| PSD Open | Power slide door open | ON or OFF | - |
| PSD Open Signal | Slide door full open signal | OFF or ON | Not applicable |