RM38T0EC _V1 General _104399 SPECIFICATIONS _0604340 M20F-FXS, M20G-FXS STARTING F

SPECIFICATIONS  M20F-FXS, M20G-FXS STARTING  SERVICE DATA  


Power Switch
Tester Connection Condition Specified Condition
12 (SS1) - 3 (GND)
6 (SS2) - 3 (GND)
11 (SS3) - 3 (GND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω
Auxiliary battery positive (+) → Terminal 5 (SWIL)
Auxiliary battery negative (-) → Terminal 3 (GND)
Illuminates

Ignition or Starter Switch Assembly
Item Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
6 (ACC) - 7 (AM1) ACC Below 1 Ω
6 (ACC) - 7 (AM1) - 8 (IG1) ON Below 1 Ω
5 (ST1) - 7 (AM1) - 8 (IG1) START Below 1 Ω