RM38T0EC _V1 General _104399 SPECIFICATIONS _0603005 M20F-FXS, M20G-FXS COOLING F

SPECIFICATIONS  M20F-FXS, M20G-FXS COOLING  SERVICE DATA  


Thermostat
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard Valve Lift 8.0 mm (0.315 in.) or more at 95°C (203°F)

Radiator
Item Condition Specified Condition
Reserve tank cap Standard pressure
(for brand-new reserve tank cap)
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi)
Minimum pressure
(for used reserve tank cap)
59 kPa (0.6 kgf/cm2, 8.6 psi)
Cooling fan motor LH Auxiliary battery voltage applied at 20°C (68°F) 6.8 to 12.7 A
Cooling fan motor RH Auxiliary battery voltage applied at 20°C (68°F) 6.8 to 12.7 A