| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard Valve Lift | 8.0 mm (0.315 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition |
|---|---|---|
| Reserve tank cap | Standard pressure
(for brand-new reserve tank cap) |
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi) |
| Minimum pressure
(for used reserve tank cap) |
59 kPa (0.6 kgf/cm2, 8.6 psi) | |
| Cooling fan motor LH | Auxiliary battery voltage applied at 20°C (68°F) | 6.8 to 12.7 A |
| Cooling fan motor RH | Auxiliary battery voltage applied at 20°C (68°F) | 6.8 to 12.7 A |