HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HEV Model)  Front Window Fogging  


DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.

Symptom Factor
Windshield frequently fogs up
·

Compressor with pulley assembly malfunction

·

Refrigerant volume (low)

·

Cooler expansion valve (opened excessively)

·

No. 1 air conditioning radiator damper servo sub-assembly malfunction

·

Mechanical locking of damper and damper link



PROCEDURE

1.PERFORM REFRIGERANT SHORTAGE CHECK
a.

Perform the Utility according to the display on the GTS.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578

b.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature* 0 to 49°C (32 to 120°F)
Blower speed HI

*: If the ambient temperature is not within the range shown, do not perform this check.


Result:
Result Amount of Refrigerant
Refrigerant correct Correct
Refrigerant shortage Insufficient


OK:

"Refrigerant correct" is displayed on the GTS.


Result:
Proceed to
OK
NG



OK

2.CHECK OPERATION

NG

2.CHECK OPERATION
a.

Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.

OK:

The air outlet mode changes to DEF mode.



Result:
Proceed to
OK
NG



OK

NG