The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| P007011 | Ambient Temperature Sensor Circuit Short to Ground | Diagnosis Condition:
Ignition switch ON Malfunction: Short (GND) in ambient temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
Thermistor assembly ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized |
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Turn the ignition switch off.
| *1 | Thermistor Assembly |
| *2 | Air Conditioning Amplifier Assembly |
Disconnect the A174 thermistor assembly connector.
Turn the ignition switch to ON and wait for 4 seconds or more.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P007015 is output | A |
| P007011 is output | B |
A
B
Disconnect the I48 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I48-1 (TAM) or A174-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| I48-14 (SG-2) or A174-2 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG