RM38T0EC _58 Vehicle Interior _104612 HEATING / AIR CONDITIONING _0601796 AIR CONDITIONING SYSTEM(for HEV Model) D

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HEV Model)  UTILITY  


REFRIGERANT SHORTAGE CHECK USING GTS


a.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Blower speed HI

*1: If the ambient temperature is not within the range shown, do not perform this check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578
HINT:
·

Refer to the GTS operator's manual for further details.

·

A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.

·

DTCs are not stored when performing the refrigerant shortage check using the GTS.



Result:
Result Amount of Refrigerant Corrective Action
Refrigerant shortage Insufficient
1.

Check for refrigerant leaks using a halogen leak detector, and repair if necessary.

2.

Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.

(Click here)


Refrigerant correct Correct -



REFRIGERANT PRESSURE HISTORY CLEAR


a.

Press the OFF switch.


b.

Perform the refrigerant pressure history clear according to the display on the GTS.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Pressure History Clear
50005 450 4579


A/C OPERATION LIMIT HISTORY COUNT CLEAR


a.

Press the OFF switch.


b.

Perform the A/C operation limit history count clear according to the display on the GTS.

Body Electrical > Air Conditioner > Utility
Tester Display
A/C Operation Limit History Count Clear
50005 450 4580