RM38T0EC _51 Engine / Hybrid System _115233 STOP AND START _0514518 STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY G

STOP AND START  STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY  INSPECTION  


PROCEDURE

Hide 84970 1.INSPECT ECO RUN CANCEL SWITCH ASSEMBLY (COMBINATION SWITCH ASSEMBLY)

a.
C401666C66
1.542,0.083 1.875,0.323 0.333,0.24 1.333,1.5 0.844,1.958 true 2.083,1.469 2.552,1.927 true 0.042,0.042 0.354,0.198 0.313,0.156 10 false *a 0.49,1.896 1.104,2.094 0.615,0.198 10 false ECU 2.635,1.854 3.25,2.052 0.615,0.198 10 false E 1.594,0.115 2.208,0.313 0.615,0.198 10 false I61
*a Component without harness connected
(Eco Run Cancel Switch Assembly (Combination Switch Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
I61-8 (ERC) - I61-5 (E) Eco run cancel switch assembly (combination switch assembly) being pushed and held Below 50 Ω
Eco run cancel switch assembly (combination switch assembly) not pushed 10 kΩ or higher


If the result is not as specified, replace the eco run cancel switch assembly (combination switch assembly).