CUSTOMIZE METER / GAUGE SYSTEM
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
The following items can be customized.
Customizing with the GTS
Select the setting by referring to the table below.
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Flasher Sound Volume Adjust | Function to change the turn signal flasher buzzer sound volume | Medium | $02:Large,$00:Medium,$01:Small | Combination meter assembly |
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| ODO Display Time After IG OFF Adjust | Function to change the trip result display time after the ignition switch is turned off | 30s | $00:30s,$01:60s,$02:600s,$03:OFF | Combination meter assembly |