81240
1.INSPECT NO. 1 ROOM LIGHT ASSEMBLY
Check the illumination.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
Apply auxiliary battery voltage to the No. 1 room light assembly and check that the lights illuminate.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T28-5 (B) - Auxiliary battery positive (+)
T28-3 (E) - Auxiliary battery negative (-) |
Room light switch on | Room light illuminates |
| T28-5 (B) - Auxiliary battery positive (+)
T28-3 (E) - Auxiliary battery negative (-) |
Room light switch off | Room light does not illuminates |
| T28-5 (B) - Auxiliary battery positive (+)
T28-1 (CTY) - Auxiliary battery negative (-) |
Room light switch off | Room light illuminate |
| T28-5 (B) - Auxiliary battery positive (+)
T28-1 (CTY) - Auxiliary battery negative (-) |
Room light switch on | Room light does not illuminate |
If the result is not as specified, replace No. 1 room light assembly.